Delta Tau Geo Direct PWM Amplifier Manual de instalación Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 53
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
Geo Direct PWM Amplifier
Power PMAC2 Drive Setup 42
Caution
At this point of the drive-motor setup, and before tuning the current loop, a couple of sanity checks can be
performed, making sure that:
Enabling the drive with a #nOut0 command does not produce any faults in neither the drive nor the
PMAC.
The current sensors are operating properly by monitoring the current measurements (i.e.
Motor[x].IaMeas, and Motor[x].IbMeas). These should be reporting values fluctuating around 0.
Frozen values, or values greater than 1000 indicate that the current sensors are not functioning
properly, or a software parameter is incorrect (i.e. Gate1[i].AdcStrobe, Motor[x].PhaseOffset,
Motor[x].AdcMask)
Subsequently, the current loop (Motor[x].IiGain, Motor[x].IpfGain, and Motor[x].IpbGain) can be tuned
using the tuning utility in the IDE software. Commutation, encoder feedback, phasing, and position loop
tuning can then be setup for closed loop control.
Note
Vista de pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 52 53

Comentarios a estos manuales

Sin comentarios