Delta Tau Geo Direct PWM Amplifier Manual de instalación Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 53
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
Geo Direct PWM Amplifier
Drive Command Structure 48
And the data is found in the lower 12 bits of ADC B for each axis:
PMAC Type
ADC B data register
Non-Turbo
Y:$C006
Turbo
Mxx06
Power PMAC2
Gate1[i].Chan[j].Adc[1]
Power PMAC3
Gate3[i].Chan[j].AdcAmp[1]
ADC B Data Register
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Phase B Current Measurement
Enhanced Mode Data
This is a read-modify-write register, once the drive is set up for enhanced mode, the following procedure
can be followed to access additional information:
Read the ADC B data register (i.e. query it in the terminal window)
Set the strobe word to the desired command code of a function (i.e. Reading Bus Voltage)
Read the lower 12 bits of ADC B to access the reported bus voltage value
Note