TB4 Manual Pulse Generator Connector
The SOCLB can easily interface a 100 pulse-per-revolution manual pulse generator. The following table
details the connection for the manual pulse generator. TB4 is the 8-pin connector located on the left side
of the following picture.
Connector Signal
TB 4, Pin 1 Channel A+
TB 4, Pin 2 Channel A-
TB 4, Pin 3 Channel B+
TB 4, Pin 4 Channel B-
TB 4, Pin 5 Ground
TB 4, Pin 6 +5Vdc
TB 4, Pin 7 Ground
TB 4, Pin 8 +5Vdc
SOCLB E-Point Jumper Configuration
When installing or replacing a SOCLB to operate with a new computer system, six hardware E-point
jumper settings must be configured and verified. The table below lists the E-point numbers with their
default settings and purpose.
Jumper Settings Purpose
E1 Not Present Reserved For Future Use
E2 Not Present Reserved For Future Use
E3 Not Present Install Jumper When SOCLB Is Interfacing
With Advantage 600 Operator Switch Panel
E4 Not Present Reserved For Future Use
E5 Not Present Reserved For Future Use
E6A ~ E6D Installed 2-3 USB Hub Circuit Not Present Is Default