Universal Serial Operator Control Logic Board
18 SOCLB Software Setup
Step 3
Make sure the In PC Bus button is selected (as shown above). PMAC NC 32 for Windows supports only
the In PC Bus option. Click on the OK button and the below displayed dialog box appears.
The PMAC board is recognized on the PC bus and can communicate with the PMAC now. To start
communicating with the PMAC board, start the Pewin32 program. Click on Pewin32 from the Windows
Start Programs/Delta Tau/Pewin 32 icon. A display closely resembling the one shown below appears.
Important items to note about the Pewin 32 Terminal window start in the title bar portion of the Pewin 32
Terminal. Starting from left to right, the information in the above displayed title bar tells us:
1. We are talking to PMAC: 0 (Device 0).
2. The current firmware revision is 1.937T6 (the T stands for test, not for general release).
3. The current firmware revision date is 10/02/2000.
4. We are talking to a Turbo PMAC.
Configuration Files for the Advantage 810
The following is an example of downloading the basic setup files for an Advantage 810 CNC being
interfaced with a milling machine. For basic milling machine operation, the following files must be
downloaded to the PMAC board:
ADV810.H
ADV810M.PLC
ADDRESS.H
OEM.H
OVRD.PLC
SPINDLE.PLC
RESET.PLC
MILL.G
MILL.M
MILL.T