Advantage 900 Remote Operator Pendant
HARDWARE SETUP
8
Advantage 900 Relay Board – (P/N: 300-603826-10x)
E POINT &
PHYSICAL
LAYOUT
DESCRIPTION Cabled
USB2.0
Wireless 1
Bluetooth
Wireless 2
Bluetooth
E1A1
Enables RS-232 Receiver Outputs. OFF 2-3 2-3
E1B1
Runs RS-232 Transceiver in normal
mode.
OFF 2-3 2-3
E1C1
Not Installed. N/A N/A N/A
E3
Emergency Stop Status loop enable.
Must be present for cabled version.
Can be used to disable Bluetooth
watchdog relay K5B.
ON ON OFF
E4
Emergency Stop Loop configuration
jumper.
Can be configured for various
functions when Bluetooth option is
present (see schematics).
ON OFF ON
E5
Emergency Stop Loop configuration
jumper.
Can be configured for various
functions when Bluetooth option is
present (see schematics).
ON OFF ON
E6
Emergency Stop Loop configuration
jumper.
Can be configured for various
functions when Bluetooth option is
present (see schematics).
OFF ON OFF
Connections
Advantage 900 Remote Operator Pendant
The Advantage 900 Remote Operator Pendant requires very few connections. The USB2.0 cabled
version simply needs to be plugged into a PC’s back panel USB2.0 port and earth grounded for
safety (a grounding wire is included with the cable assembly). An Emergency Stop Loop is
included to interface with the machines safety circuitry. This loop passes through a normally
closed set of contacts in the Emergency Stop switch housed in the handheld unit. The Advantage
900 Relay board provides a convenient method to interface this circuitry.
The wireless version includes a charging cable which connects directly to a standard PC disk
drive connector. The Emergency Stop circuitry is not present on the wireless unit and is replaced
by a Stop circuit which is electronically sensed and distributed at the Advantage 900 Relay
Board.