Advantage 900 Remote Operator Pendant
SOFTWARE SETUP
14
#define LT_FEED_HOLD_M M2016
#define E_STOP_IN_M M2017
//Dual Port Ram Memory Map Locations.
//PcommServer Automatically writes to these locations.
M2000->Y:$60FD8,0,1
M2001->Y:$60FD8,1,1
M2002->Y:$60FD8,2,1
M2003->Y:$60FD8,3,1
M2004->Y:$60FD8,4,1
M2005->Y:$60FD8,5,1
M2006->Y:$60FD8,6,1
M2007->Y:$60FD8,7,1
M2008->Y:$60FD8,8,1
M2009->Y:$60FD8,9,1
M2010->Y:$60FD8,10,1
M2011->Y:$60FD8,11,1
M2012->Y:$60FD8,12,1
M2013->Y:$60FD8,13,1
M2014->Y:$60FD8,14,1
M2015->X:$60FD8,0,1
M2016->X:$60FD8,1,1
M2017->Y:$60FD0,8,1